I-Microcuvette ye-Hemoglobin Analyzer

Incazelo emfushane:

Ukusetshenziswa Okuhlosiwe

◆I-microcuvette isetshenziswa ne-H7 series hemoglobin analyzer ukuze kutholwe inani le-hemoglobin egazini lonke lomuntu.

Umgomo wokuhlola

◆I-microcuvette inesikhala esiwugqinsi esingaguquki sokufaka isifanekiso segazi, futhi i-microcuvette ine-reagent eshintshayo ngaphakathi yokuqondisa isifanekiso ukuze sigcwalise i-microcuvette.I-microcuvette egcwele isampula ifakwa kudivayisi yokubona ye-hemoglobin analyzer, futhi ubude begagasi obuthile bokukhanya budluliselwa ngesampula yegazi, futhi i-hemoglobin analyzer iqoqa isignali yokubona futhi ihlaziye futhi ibale okuqukethwe kwe-hemoglobin yesampula.Umgomo oyinhloko yi-spectrophotometry.


Imininingwane Yomkhiqizo

I-Microcuvette ye-Hemoglobin analyzer

 

I-Microcuvette ye-Hemoglobin analyzer0

 

I-Hemoglobin analyzer microcuvette

 

Imininingwane Yomkhiqizo:

◆ Material: i-polystyrene

◆Impilo Yeshelufu: Iminyaka emi-2

◆ Izinga lokushisa lokugcina: 2°C35°C

◆Ukuswakama Okuhlobene≤85%

◆Isisindo: 0.5g

◆Ukupakisha: 50 izingcezu/ibhodlela

Inani elihle/ububanzi bereferensi Ububanzi bereferensi:

◆Abesilisa abadala: 130-175g/dL

◆Abesifazane abadala: 115-150g/dL

◆Usana: 110-120g/dL

◆Ingane: 120-140g/dL

Umphumela Wokuhlola

◆Ibanga lokubonisa isilinganiso lingu-0-250g/L.I-coagulation ingase ibangele isampula yegazi ukuthi ihluleke ukugcwalisa i-microcuvette, okuholela ekulinganisweni okungalungile.

◆I-Hemolysis ingathinta imiphumela yokuhlolwa.

Umkhawulo Wendlela Yokuhlola

◆Ukuxilongwa nokwelashwa akufanele kuncike kuphela emphumeleni wokuhlolwa.Umlando womtholampilo kanye nokunye ukuhlolwa kwaselabhorethri kufanele kubhekwe

Ukucaciswa kokusebenza

◆Akunalutho:1g/L

◆Ukuphindaphinda:phakathi kwebanga 30g/L kuya ku-100g/L, SD3g/L;phakathi kwebanga elingu-101g/L kuya ku-250g/L, i-CV1.5%

◆Linearity:phakathi kwebanga elingu-30g/L kuya ku-250g/L, r0.99

◆Ukunemba:I-coefficient (r) yokuhlolwa kokuqhathanisa ithi0.99, futhi ukuchezuka okuhlobene kungu-5%

◆Umehluko phakathi kwenqwaba≤5g/L

Inqubo Yokuhlola Ukuhlolwa kwegazi kwe-EDTA:

◆Amasampula agciniwe kufanele abuyiselwe ekamelweni lokushisa futhi axutshwe kahle ngaphambi kokuhlolwa.

◆Sebenzisa i-micropipette noma i-pipette ukuze udonse igazi elingekho ngaphansi kuka-10μL kusilayidi sengilazi ehlanzekile noma enye indawo ehlanzekile ye-hydrophobic.

◆ Ngokusebenzisa ithiphu le-reagent ukuze uxhumane nesampula, isampula ingena ngaphansi kwesenzo se-capillary futhi igcwalise ucezu lwe-reagent.

◆Sula ngokucophelela noma iyiphi isampula engaphezulu kwe-microcuvette.

◆Beka i-microcuvette kumphathi we-microcuvette we-hemoglobin analyzer bese ucindezela isibambi kumshini wokuhlaziya ukuze uqale ukulinganisa.